# git rev-parse -q --verify 9187210eee7d87eea37b45ea93454a88681894a4^{commit} 9187210eee7d87eea37b45ea93454a88681894a4 already have revision, skipping fetch # git checkout -q -f -B kisskb 9187210eee7d87eea37b45ea93454a88681894a4 # git clean -qxdf # < git log -1 # commit 9187210eee7d87eea37b45ea93454a88681894a4 # Merge: 1f440397665f ed1f164038b5 # Author: Linus Torvalds # Date: Tue Mar 12 17:44:08 2024 -0700 # # Merge tag 'net-next-6.9' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-next # # Pull networking updates from Jakub Kicinski: # "Core & protocols: # # - Large effort by Eric to lower rtnl_lock pressure and remove locks: # # - Make commonly used parts of rtnetlink (address, route dumps # etc) lockless, protected by RCU instead of rtnl_lock. # # - Add a netns exit callback which already holds rtnl_lock, # allowing netns exit to take rtnl_lock once in the core instead # of once for each driver / callback. # # - Remove locks / serialization in the socket diag interface. # # - Remove 6 calls to synchronize_rcu() while holding rtnl_lock. # # - Remove the dev_base_lock, depend on RCU where necessary. # # - Support busy polling on a per-epoll context basis. Poll length and # budget parameters can be set independently of system defaults. # # - Introduce struct net_hotdata, to make sure read-mostly global # config variables fit in as few cache lines as possible. # # - Add optional per-nexthop statistics to ease monitoring / debug of # ECMP imbalance problems. # # - Support TCP_NOTSENT_LOWAT in MPTCP. # # - Ensure that IPv6 temporary addresses' preferred lifetimes are long # enough, compared to other configured lifetimes, and at least 2 sec. # # - Support forwarding of ICMP Error messages in IPSec, per RFC 4301. # # - Add support for the independent control state machine for bonding # per IEEE 802.1AX-2008 5.4.15 in addition to the existing coupled # control state machine. # # - Add "network ID" to MCTP socket APIs to support hosts with multiple # disjoint MCTP networks. # # - Re-use the mono_delivery_time skbuff bit for packets which user # space wants to be sent at a specified time. Maintain the timing # information while traversing veth links, bridge etc. # # - Take advantage of MSG_SPLICE_PAGES for RxRPC DATA and ACK packets. # # - Simplify many places iterating over netdevs by using an xarray # instead of a hash table walk (hash table remains in place, for use # on fastpaths). # # - Speed up scanning for expired routes by keeping a dedicated list. # # - Speed up "generic" XDP by trying harder to avoid large allocations. # # - Support attaching arbitrary metadata to netconsole messages. # # Things we sprinkled into general kernel code: # # - Enforce VM_IOREMAP flag and range in ioremap_page_range and # introduce VM_SPARSE kind and vm_area_[un]map_pages (used by # bpf_arena). # # - Rework selftest harness to enable the use of the full range of ksft # exit code (pass, fail, skip, xfail, xpass). # # Netfilter: # # - Allow userspace to define a table that is exclusively owned by a # daemon (via netlink socket aliveness) without auto-removing this # table when the userspace program exits. Such table gets marked as # orphaned and a restarting management daemon can re-attach/regain # ownership. # # - Speed up element insertions to nftables' concatenated-ranges set # type. Compact a few related data structures. # # BPF: # # - Add BPF token support for delegating a subset of BPF subsystem # functionality from privileged system-wide daemons such as systemd # through special mount options for userns-bound BPF fs to a trusted # & unprivileged application. # # - Introduce bpf_arena which is sparse shared memory region between # BPF program and user space where structures inside the arena can # have pointers to other areas of the arena, and pointers work # seamlessly for both user-space programs and BPF programs. # # - Introduce may_goto instruction that is a contract between the # verifier and the program. The verifier allows the program to loop # assuming it's behaving well, but reserves the right to terminate # it. # # - Extend the BPF verifier to enable static subprog calls in spin lock # critical sections. # # - Support registration of struct_ops types from modules which helps # projects like fuse-bpf that seeks to implement a new struct_ops # type. # # - Add support for retrieval of cookies for perf/kprobe multi links. # # - Support arbitrary TCP SYN cookie generation / validation in the TC # layer with BPF to allow creating SYN flood handling in BPF # firewalls. # # - Add code generation to inline the bpf_kptr_xchg() helper which # improves performance when stashing/popping the allocated BPF # objects. # # Wireless: # # - Add SPP (signaling and payload protected) AMSDU support. # # - Support wider bandwidth OFDMA, as required for EHT operation. # # Driver API: # # - Major overhaul of the Energy Efficient Ethernet internals to # support new link modes (2.5GE, 5GE), share more code between # drivers (especially those using phylib), and encourage more # uniform behavior. Convert and clean up drivers. # # - Define an API for querying per netdev queue statistics from # drivers. # # - IPSec: account in global stats for fully offloaded sessions. # # - Create a concept of Ethernet PHY Packages at the Device Tree level, # to allow parameterizing the existing PHY package code. # # - Enable Rx hashing (RSS) on GTP protocol fields. # # Misc: # # - Improvements and refactoring all over networking selftests. # # - Create uniform module aliases for TC classifiers, actions, and # packet schedulers to simplify creating modprobe policies. # # - Address all missing MODULE_DESCRIPTION() warnings in networking. # # - Extend the Netlink descriptions in YAML to cover message # encapsulation or "Netlink polymorphism", where interpretation of # nested attributes depends on link type, classifier type or some # other "class type". # # Drivers: # # - Ethernet high-speed NICs: # - Add a new driver for Marvell's Octeon PCI Endpoint NIC VF. # - Intel (100G, ice, idpf): # - support E825-C devices # - nVidia/Mellanox: # - support devices with one port and multiple PCIe links # - Broadcom (bnxt): # - support n-tuple filters # - support configuring the RSS key # - Wangxun (ngbe/txgbe): # - implement irq_domain for TXGBE's sub-interrupts # - Pensando/AMD: # - support XDP # - optimize queue submission and wakeup handling (+17% bps) # - optimize struct layout, saving 28% of memory on queues # # - Ethernet NICs embedded and virtual: # - Google cloud vNIC: # - refactor driver to perform memory allocations for new queue # config before stopping and freeing the old queue memory # - Synopsys (stmmac): # - obey queueMaxSDU and implement counters required by 802.1Qbv # - Renesas (ravb): # - support packet checksum offload # - suspend to RAM and runtime PM support # # - Ethernet switches: # - nVidia/Mellanox: # - support for nexthop group statistics # - Microchip: # - ksz8: implement PHY loopback # - add support for KSZ8567, a 7-port 10/100Mbps switch # # - PTP: # - New driver for RENESAS FemtoClock3 Wireless clock generator. # - Support OCP PTP cards designed and built by Adva. # # - CAN: # - Support recvmsg() flags for own, local and remote traffic on CAN # BCM sockets. # - Support for esd GmbH PCIe/402 CAN device family. # - m_can: # - Rx/Tx submission coalescing # - wake on frame Rx # # - WiFi: # - Intel (iwlwifi): # - enable signaling and payload protected A-MSDUs # - support wider-bandwidth OFDMA # - support for new devices # - bump FW API to 89 for AX devices; 90 for BZ/SC devices # - MediaTek (mt76): # - mt7915: newer ADIE version support # - mt7925: radio temperature sensor support # - Qualcomm (ath11k): # - support 6 GHz station power modes: Low Power Indoor (LPI), # Standard Power) SP and Very Low Power (VLP) # - QCA6390 & WCN6855: support 2 concurrent station interfaces # - QCA2066 support # - Qualcomm (ath12k): # - refactoring in preparation for Multi-Link Operation (MLO) # support # - 1024 Block Ack window size support # - firmware-2.bin support # - support having multiple identical PCI devices (firmware needs # to have ATH12K_FW_FEATURE_MULTI_QRTR_ID) # - QCN9274: support split-PHY devices # - WCN7850: enable Power Save Mode in station mode # - WCN7850: P2P support # - RealTek: # - rtw88: support for more rtw8811cu and rtw8821cu devices # - rtw89: support SCAN_RANDOM_SN and SET_SCAN_DWELL # - rtlwifi: speed up USB firmware initialization # - rtwl8xxxu: # - RTL8188F: concurrent interface support # - Channel Switch Announcement (CSA) support in AP mode # - Broadcom (brcmfmac): # - per-vendor feature support # - per-vendor SAE password setup # - DMI nvram filename quirk for ACEPC W5 Pro" # # * tag 'net-next-6.9' of git://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-next: (2255 commits) # nexthop: Fix splat with CONFIG_DEBUG_PREEMPT=y # nexthop: Fix out-of-bounds access during attribute validation # nexthop: Only parse NHA_OP_FLAGS for dump messages that require it # nexthop: Only parse NHA_OP_FLAGS for get messages that require it # bpf: move sleepable flag from bpf_prog_aux to bpf_prog # bpf: hardcode BPF_PROG_PACK_SIZE to 2MB * num_possible_nodes() # selftests/bpf: Add kprobe multi triggering benchmarks # ptp: Move from simple ida to xarray # vxlan: Remove generic .ndo_get_stats64 # vxlan: Do not alloc tstats manually # devlink: Add comments to use netlink gen tool # nfp: flower: handle acti_netdevs allocation failure # net/packet: Add getsockopt support for PACKET_COPY_THRESH # net/netlink: Add getsockopt support for NETLINK_LISTEN_ALL_NSID # selftests/bpf: Add bpf_arena_htab test. # selftests/bpf: Add bpf_arena_list test. # selftests/bpf: Add unit tests for bpf_arena_alloc/free_pages # bpf: Add helper macro bpf_addr_space_cast() # libbpf: Recognize __arena global variables. # bpftool: Recognize arena map type # ... # < /opt/cross/kisskb/korg/gcc-13.1.0-nolibc/powerpc64-linux/bin/powerpc64-linux-gcc --version # < /opt/cross/kisskb/korg/gcc-13.1.0-nolibc/powerpc64-linux/bin/powerpc64-linux-ld --version # < git log --format=%s --max-count=1 9187210eee7d87eea37b45ea93454a88681894a4 # make -s -j 32 ARCH=powerpc O=/kisskb/build/linus_allmodconfig_powerpc-gcc13 CROSS_COMPILE=/opt/cross/kisskb/korg/gcc-13.1.0-nolibc/powerpc64-linux/bin/powerpc64-linux- allmodconfig # Added to kconfig CONFIG_BUILD_DOCSRC=n # Added to kconfig CONFIG_SAMPLES=n # Added to kconfig CONFIG_OPTIMIZE_INLINING=n # Added to kconfig CONFIG_BPF_PRELOAD=n # Added to kconfig CONFIG_GCC_PLUGINS=n # Added to kconfig # < make -s -j 32 ARCH=powerpc O=/kisskb/build/linus_allmodconfig_powerpc-gcc13 CROSS_COMPILE=/opt/cross/kisskb/korg/gcc-13.1.0-nolibc/powerpc64-linux/bin/powerpc64-linux- help # make -s -j 32 ARCH=powerpc O=/kisskb/build/linus_allmodconfig_powerpc-gcc13 CROSS_COMPILE=/opt/cross/kisskb/korg/gcc-13.1.0-nolibc/powerpc64-linux/bin/powerpc64-linux- olddefconfig # make -s -j 32 ARCH=powerpc O=/kisskb/build/linus_allmodconfig_powerpc-gcc13 CROSS_COMPILE=/opt/cross/kisskb/korg/gcc-13.1.0-nolibc/powerpc64-linux/bin/powerpc64-linux- /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/a3m071.dts:135.15-137.4 arch/powerpc/boot/dts/a3m071.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/mpc5121.dtsi:397.13-406.5: Warning (spi_bus_bridge): /soc@80000000/psc@11400: node name for SPI buses should be 'spi' also defined at /kisskb/src/arch/powerpc/boot/dts/ac14xx.dts:305.19-326.5 /kisskb/src/arch/powerpc/boot/dts/mpc5121.dtsi:409.13-418.5: Warning (spi_bus_bridge): /soc@80000000/psc@11500: node name for SPI buses should be 'spi' also defined at /kisskb/src/arch/powerpc/boot/dts/ac14xx.dts:329.19-344.5 arch/powerpc/boot/dts/ac14xx.dtb: Warning (spi_bus_reg): Failed prerequisite 'spi_bus_bridge' /kisskb/src/arch/powerpc/boot/dts/mpc5121.dtsi:508.20-525.4: Warning (interrupt_provider): /pci@80008500: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/ac14xx.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/amigaone.dts:57.9-163.5: Warning (interrupt_provider): /pci@80000000/isa@7: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/amigaone.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/bluestone.dts:272.13-277.7: Warning (i2c_bus_reg): /plb/opb/i2c@ef600700/sttm@4C: I2C bus unit address format error, expected "4c" /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/cm5200.dts:70.15-72.4 arch/powerpc/boot/dts/cm5200.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/ep8248e.dts:101.13-190.5: Warning (interrupt_provider): /soc@f0000000/cpm@119c0: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/ep8248e.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/ep88xc.dts:122.13-131.5: Warning (interrupt_provider): /soc@fa200000/pcmcia@80: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/ep88xc.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/gef_ppc9a.dts:211.22-213.4: Warning (pci_bridge): /pcie@fef09000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:129.9-143.4: Warning (pci_bridge): /pcie@fef09000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/gef_ppc9a.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/gef_ppc9a.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/gef_ppc9a.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsl/gef_ppc9a.dts:195.22-209.4: Warning (interrupt_provider): /pcie@fef08000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:92.7-117.3 /kisskb/src/arch/powerpc/boot/dts/fsl/gef_ppc9a.dts:211.22-213.4: Warning (interrupt_provider): /pcie@fef09000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 arch/powerpc/boot/dts/fsl/gef_ppc9a.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/gef_sbc610.dts:209.22-211.4: Warning (pci_bridge): /pcie@fef09000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:129.9-143.4: Warning (pci_bridge): /pcie@fef09000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/gef_sbc610.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:392.24-397.5: Warning (interrupt_provider): /plb4/plb6-system-hung-irq: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/gef_sbc610.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:399.16-404.5: Warning (interrupt_provider): /plb4/l2-error-irq: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/gef_sbc610.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:406.17-411.5: Warning (interrupt_provider): /plb4/plb6-plb4-irq: '#interrupt-cells' found, but node is not an interrupt provider /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:413.16-418.5: Warning (interrupt_provider): /plb4/plb4-ahb-irq: '#interrupt-cells' found, but node is not an interrupt provider /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:420.18-425.5: Warning (interrupt_provider): /plb4/opbd-error-irq: '#interrupt-cells' found, but node is not an interrupt provider /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:427.17-432.5: Warning (interrupt_provider): /plb4/cmu-error-irq: '#interrupt-cells' found, but node is not an interrupt provider /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:434.18-439.5: Warning (interrupt_provider): /plb4/conf-error-irq: '#interrupt-cells' found, but node is not an interrupt provider /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:441.13-446.5: Warning (interrupt_provider): /plb4/mc-ue-irq: '#interrupt-cells' found, but node is not an interrupt provider /kisskb/src/arch/powerpc/boot/dts/fsp2.dts:448.21-453.5: Warning (interrupt_provider): /plb4/reset-warning-irq: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsp2.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/gef_sbc610.dts:193.22-207.4: Warning (interrupt_provider): /pcie@fef08000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:92.7-117.3 /kisskb/src/arch/powerpc/boot/dts/fsl/gef_sbc610.dts:209.22-211.4: Warning (interrupt_provider): /pcie@fef09000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 arch/powerpc/boot/dts/fsl/gef_sbc610.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/gef_sbc310.dts:217.22-231.4: Warning (interrupt_provider): /pcie@fef09000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 arch/powerpc/boot/dts/fsl/gef_sbc310.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/kmcoge4.dts:196.23-198.4: Warning (pci_bridge): /pcie@ffe201000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p2041si-post.dtsi:87.7-113.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p2041si-post.dtsi:97.9-112.4: Warning (pci_bridge): /pcie@ffe201000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/kmcoge4.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/kmcoge4.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/kmcoge4.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8544ds.dtsi:154.11-204.6: Warning (interrupt_provider): /pcie@e000b000/pcie@0/uli1575@0/isa@1e: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/mpc8544ds.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8572ds.dtsi:375.11-425.6: Warning (interrupt_provider): /pcie@ffe08000/pcie@0/uli1575@0/isa@1e: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/mpc8572ds.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8572ds.dtsi:375.11-425.6: Warning (interrupt_provider): /pcie@ffe08000/pcie@0/uli1575@0/isa@1e: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/mpc8572ds_camp_core0.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8572ds.dtsi:375.11-425.6: Warning (interrupt_provider): /pcie@fffe08000/pcie@0/uli1575@0/isa@1e: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/mpc8572ds_36b.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8572ds.dtsi:375.11-425.6: Warning (interrupt_provider): /pcie@ffe08000/pcie@0/uli1575@0/isa@1e: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/mpc8572ds_camp_core1.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/mvme7100.dts:135.22-137.4: Warning (pci_bridge): /pcie@f1008000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:92.7-117.3 /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:102.9-116.4: Warning (pci_bridge): /pcie@f1008000/pcie@0: missing ranges for PCI bridge (or not a bridge) /kisskb/src/arch/powerpc/boot/dts/fsl/mvme7100.dts:139.22-141.4: Warning (pci_bridge): /pcie@f1009000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:129.9-143.4: Warning (pci_bridge): /pcie@f1009000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/mvme7100.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/mvme7100.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/mvme7100.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsl/mvme7100.dts:30.11-32.6: Warning (i2c_bus_reg): /soc@f1000000/i2c@3000/rtc@68: missing or empty reg property /kisskb/src/arch/powerpc/boot/dts/fsl/mvme7100.dts:135.22-137.4: Warning (interrupt_provider): /pcie@f1008000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:92.7-117.3 /kisskb/src/arch/powerpc/boot/dts/fsl/mvme7100.dts:139.22-141.4: Warning (interrupt_provider): /pcie@f1009000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8641si-post.dtsi:119.7-144.3 arch/powerpc/boot/dts/fsl/mvme7100.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/oca4080.dts:132.23-134.4: Warning (pci_bridge): /pcie@ffe200000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p4080si-post.dtsi:58.7-84.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p4080si-post.dtsi:68.9-83.4: Warning (pci_bridge): /pcie@ffe200000/pcie@0: missing ranges for PCI bridge (or not a bridge) /kisskb/src/arch/powerpc/boot/dts/fsl/oca4080.dts:136.23-138.4: Warning (pci_bridge): /pcie@ffe201000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p4080si-post.dtsi:87.7-113.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p4080si-post.dtsi:97.9-112.4: Warning (pci_bridge): /pcie@ffe201000/pcie@0: missing ranges for PCI bridge (or not a bridge) /kisskb/src/arch/powerpc/boot/dts/fsl/oca4080.dts:140.23-142.4: Warning (pci_bridge): /pcie@ffe202000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p4080si-post.dtsi:116.7-142.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p4080si-post.dtsi:126.9-141.4: Warning (pci_bridge): /pcie@ffe202000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/oca4080.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/oca4080.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/oca4080.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/mgcoge.dts:105.13-230.5: Warning (interrupt_provider): /soc@f0000000/cpm@119c0: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/mgcoge.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/motionpro.dts:84.15-86.4 arch/powerpc/boot/dts/motionpro.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/p1020rdb-pd.dts:189.11-193.6: Warning (spi_bus_reg): /soc@ffe00000/spi@7000/slic@0: SPI bus unit address format error, expected "1" /kisskb/src/arch/powerpc/boot/dts/fsl/p1020rdb-pd.dts:195.11-199.6: Warning (spi_bus_reg): /soc@ffe00000/spi@7000/slic@1: SPI bus unit address format error, expected "2" /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@ffe00000/mdio@24000/ethernet-phy@0:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@ffe00000/mdio@24000/ethernet-phy@1:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@fffe00000/mdio@24000/ethernet-phy@0:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@fffe00000/mdio@24000/ethernet-phy@1:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/mpc885ads.dts:127.13-136.5: Warning (interrupt_provider): /soc@ff000000/pcmcia@80: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/mpc885ads.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@ffe00000/mdio@24000/ethernet-phy@0:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@ffe00000/mdio@24000/ethernet-phy@1:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/mvme5100.dts:155.7-177.5: Warning (interrupt_provider): /pci@feff0000/isa: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/mvme5100.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@fffe00000/mdio@24000/ethernet-phy@0:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/fsl/pq3-mpic.dtsi:38.2-25: Warning (interrupts_property): /soc@fffe00000/mdio@24000/ethernet-phy@1:#interrupt-cells: size is (8), expected multiple of 16 /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/o2d.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/o2d300.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/o2dnt2.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/p2020ds.dtsi:274.11-324.6: Warning (interrupt_provider): /pcie@ffe09000/pcie@0/uli1575@0/isa@1e: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/fsl/p2020ds.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/p2020rdb-pc_36b.dts:59.23-62.4: Warning (pci_bridge): /pcie@fffe08000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p2020si-post.dtsi:102.7-129.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p2020si-post.dtsi:112.9-128.4: Warning (pci_bridge): /pcie@fffe08000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/p2020rdb-pc_36b.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/p2020rdb-pc_36b.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/p2020rdb-pc_36b.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/o2i.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/p2020rdb-pc_32b.dts:59.22-62.4: Warning (pci_bridge): /pcie@ffe08000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p2020si-post.dtsi:102.7-129.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p2020si-post.dtsi:112.9-128.4: Warning (pci_bridge): /pcie@ffe08000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/p2020rdb-pc_32b.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/p2020rdb-pc_32b.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/p2020rdb-pc_32b.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/o3dnt.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/o2mnt.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/fsl/p2020rdb.dts:251.22-254.4: Warning (pci_bridge): /pcie@ffe08000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/p2020si-post.dtsi:43.7-69.3 /kisskb/src/arch/powerpc/boot/dts/fsl/p2020si-post.dtsi:53.9-68.4: Warning (pci_bridge): /pcie@ffe08000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/p2020rdb.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/p2020rdb.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/p2020rdb.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsl/ppa8548.dts:34.22-37.4: Warning (pci_bridge): /pci@fe0008000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8548si-post.dtsi:43.7-51.3 /kisskb/src/arch/powerpc/boot/dts/fsl/ppa8548.dts:39.22-42.4: Warning (pci_bridge): /pci@fe0009000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8548si-post.dtsi:54.7-62.3 /kisskb/src/arch/powerpc/boot/dts/fsl/ppa8548.dts:44.23-47.4: Warning (pci_bridge): /pcie@fe000a000: missing ranges for PCI bridge (or not a bridge) also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8548si-post.dtsi:65.7-90.3 /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8548si-post.dtsi:74.9-89.4: Warning (pci_bridge): /pcie@fe000a000/pcie@0: missing ranges for PCI bridge (or not a bridge) arch/powerpc/boot/dts/fsl/ppa8548.dtb: Warning (unit_address_format): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/ppa8548.dtb: Warning (pci_device_reg): Failed prerequisite 'pci_bridge' arch/powerpc/boot/dts/fsl/ppa8548.dtb: Warning (pci_device_bus_num): Failed prerequisite 'pci_bridge' /kisskb/src/arch/powerpc/boot/dts/fsl/ppa8548.dts:34.22-37.4: Warning (interrupt_provider): /pci@fe0008000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8548si-post.dtsi:43.7-51.3 /kisskb/src/arch/powerpc/boot/dts/fsl/ppa8548.dts:39.22-42.4: Warning (interrupt_provider): /pci@fe0009000: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/fsl/mpc8548si-post.dtsi:54.7-62.3 arch/powerpc/boot/dts/fsl/ppa8548.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/mpc5121.dtsi:457.13-466.5: Warning (spi_bus_bridge): /soc@80000000/psc@11900: node name for SPI buses should be 'spi' also defined at /kisskb/src/arch/powerpc/boot/dts/pdm360ng.dts:172.13-185.5 arch/powerpc/boot/dts/pdm360ng.dtb: Warning (spi_bus_reg): Failed prerequisite 'spi_bus_bridge' /kisskb/src/arch/powerpc/boot/dts/mpc5121.dtsi:508.20-525.4: Warning (interrupt_provider): /pci@80008500: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/pdm360ng.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/sam440ep.dts:266.22-287.5: Warning (interrupt_provider): /plb/pci@ec000000: '#interrupt-cells' found, but node is not an interrupt provider arch/powerpc/boot/dts/sam440ep.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' /kisskb/src/arch/powerpc/boot/dts/stxssa8555.dts:342.15-351.5: Warning (pci_device_reg): /pci@e0008000/i8259@19000: PCI unit address format error, expected "12,0" /kisskb/src/arch/powerpc/boot/dts/stxssa8555.dts:331.3-21: Warning (pci_device_bus_num): /pci@e0008000/i8259@19000:bus-range: PCI bus number 1 out of range, expected (0 - 0) /kisskb/src/arch/powerpc/boot/dts/mpc5200b.dtsi:267.20-282.4: Warning (interrupt_provider): /pci@f0000d00: '#interrupt-cells' found, but node is not an interrupt provider also defined at /kisskb/src/arch/powerpc/boot/dts/uc101.dts:100.15-102.4 arch/powerpc/boot/dts/uc101.dtb: Warning (interrupt_map): Failed prerequisite 'interrupt_provider' Completed OK # rm -rf /kisskb/build/linus_allmodconfig_powerpc-gcc13 # Build took: 0:30:06.518212